Eurex Gateway

7.18.50.10

Released: May 23, 2019 File Size: 70590272
Package Contents:
No notes available.

Important Notes

Eurex Gateway 7.18.50 is released to support the Eurex T7 7.1 upgrade occurring on May 27.

Why Should I Upgrade?

Eurex Gateway 7.18.50 is released to support the Eurex T7 7.1 upgrade occurring on May 27. Customers must upgrade to this version after the close on Friday, May 24, and prior to the open on Monday, May 27.

As of this upgrade, Eurex Low Frequency ETI sessions will no longer be able to point to Connection Gateways, and will need to connect directly to the Trading Gateways themselves. IP addresses of the new Primary and Secondary Trading Gateways are available via the Eurex Member Portal under: Technical Connection -> Request and Configuration - > Current Configuration

Alternatively, customers can target any of the LF trading gateways listed in the Eurex Network Access Guide. Note that an attempt to connect to an LF gateway already at maximum capacity will result in an error message indicating that a different LF trading gateway should be used.

System Requirements

Eurex Gateway 7.18.50 is released to support the Eurex T7 7.1 upgrade occurring on May 27. Customers must upgrade to this version after the close on Friday, May 24, and prior to the open on Monday, May 27.

As of this upgrade, Eurex Low Frequency ETI sessions will no longer be able to point to Connection Gateways, and will need to connect directly to the Trading Gateways themselves. IP addresses of the new Primary and Secondary Trading Gateways are available via the Eurex Member Portal under: Technical Connection -> Request and Configuration - > Current Configuration

Alternatively, customers can target any of the LF trading gateways listed in the Eurex Network Access Guide. Note that an attempt to connect to an LF gateway already at maximum capacity will result in an error message indicating that a different LF trading gateway should be used.

Installation Notes

Customers should backup the existing multicastgroups.cfg file prior to the upgrade, and then replace the file after the upgrade has taken place.

Please note the following changes required in the Order Server section of the hostinfo.cfg:

1. The ConnectionGW1 and 2 parameters have been deprecated. Customers must now use the new PrimaryIP and SecondaryIP parameters.
2. Customers must add the IsLFSession=true parameter on all Order Sessions. Set the value to true for LF sessions, and false for HF sessions.
3. Port must be changed to 19006 in order to connect to the Low Frequency gateways. Please see the Eurex Network Access Guide for details.

Sample configuration:

OLD, pre-7.18.45:
[OrderServerSession_1]
Member=
BusinessUnit=
SessionId=
SessionPassword=
NetworkInterfaceFeed1=
NetworkInterfaceFeed2=
ConnectionGw1=DEPRECATED
ConnectionGw2= DEPRECATED

Port=
LogSendReceive=0
SendRegulatoryID=0
AlgoRange=

NEW with 7.18.45:
[OrderServerSession_2]
Member=
BusinessUnit=
SessionId=
SessionPassword=
NetworkInterfaceFeed1=
NetworkInterfaceFeed2=
PrimaryIP=REQUIRED
SecondaryIP= REQUIRED

port=19006
LogSendReceive=0
SendRegulatoryID=1
AlgoRange=
IsLFSession= REQUIRED

Enhancements

Fixes

Known Issues

  1. Please note that instruments created intraday will function correctly but will display a Status of "Unknown", regardless of the actual market state. The Status will be corrected upon Price Server restart, or the following trading day. This issue will be resolved in a future release.